HOM-BESS418125W
2.webp
WPS图片(1)(1775179759708).webp
HOM-BESS418125W

HOM-BESS418125W

Benefits & features: Ø Supports PV input up to 200% of the inverter's rated DC power, maximising solar utilisation Ø Supports up to 21A PV input current, compatible with the latest high-power PV modules Ø 160% overload for 200ms in off-grid mode, ensuring stable startup of motors and water pumps Ø Two independent battery connections, allowing more flexible system configuration Ø Smart port enables multiple energy source inputs, including grid-tied inverters, diesel generators, and wind turbines Ø Seamless on/off-grid switching in under 10ms, guaranteeing uninterrupted powe supply Ø Supports up to 10 units in parallel. For systems with more than 6 units, use of power distribution cabinet is recommended

E-Mail

Lewis@sz-homsolar.com

>> Product Detail

Specification:

Model HOM-BESS261125W HOM-BESS418125W

System Technical Specifications

 

Nominal Energy

261.24 kWh

418 kWh

Nominal DC Voltage

832 V

665.6 V

Number of Battery Pack

5

8

Dimensions (WxDxH) (no contain inverter)

1300*1320*2380

mm

Weight (no contain inverter)

~2320kgs

~3500kgs

Endosure Rating

IP55

Cooling Method

Liquid-cooling

Communication Port

CAN/Ethernet /485

Warranty

10 Years

Certification (Battery)

UN38.3, IEC62619, CE, CEI 0-21, VDE-AR-N 4105, IEC 62109

Certification (Inverter)

IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011

 

Battery Pack Model

SEA314M1P52S

Rated Energy

52.25 kWh

Rated Voltage

166.4V

Rated Capacity

314 Ah

Rated Power

0.5C

Voltage Range

145.6~187.2V

IP Rating

IP67

Size(mm)

W810*D1145*H238

 

Inverter Model

S6-EH3P(125)K10-NV-YD-H

Battery

 

Battery Chemistry

Li-ion

Battery Voltage Range

300~950V

Max.Charge/Discharge Current

200 A/100 A+100A

Number of Battery Ports

2

Max.Charge/Discharge Current of Each Port

100A

Communication

CAN/RS485

Input DC (PV side)

 

Recommended Max. PV Array Size

250 kW

Max. Usable PV Input Power

250 kW

Max.Input Voltage

1000 V

Rated Voltage

600V

Start-up Voltage

180V

MPPT Voltage Range

150-950V

Max.Input Current

10x42A

Max. Short Circuit Vurrent

10x60A

MPPT Number / Max. Input Strings Number

10/20

Output/Input AC(Grid side)

 

Rated Output Power

125 kW

Max.Apparent Output Power

125 kVA

Rated Grid Voltage

3/N/PE, 220 V /380 V, 230 V/ 400 V

Rated Grid Frequency

50 Hz/ 60 Hz

Rated Grid Output Current

189.9 A/180.4A

Power Factor

>0.99 (0.8 leading -0.8 lagging)

THDi

<3%

Max.Input Current

250 A

 

Output AC (Back-up)  

Rated Output Power

125 kW

Max. Apparent Output Power

1.2 times of rated power, 100 s; 1.4 times of rated power, 10 s; 1.6 times of rated power, 200 ms

Back-up Switch Time

<10ms

Rated Output Voltage

3/N/PE, 220 V / 380 V, 230V/400V

Rated Frequency

50 Hz/60 Hz

THDv(@linear load)

<2%

Input AC (Generator)

 

Max.Input Power

125 kW

Rated Input Current

189.9 A/180.4 A

Rated Input Voltage

3/N/PE, 220 V / 380 V, 230 V / 400 V

Rated Input Frequency

50 Hz/60 Hz

General Data

 

Max. Allowable Phase Imbalance (Grid & Back-up)

100%

Max. Power Per Phase (Grid & Back-up)

41.66 kW

Max Parallel Connection Sets

Supports up to 10 units in parallel. For systems with more than 6 units, use of power distribution cabinet is recommended

Topology

Transformerless

Cooling Concept

Intelligent fan-cooling

If the size and parameters of the product are changed, the latest information will prevail without further notice. 

 

>> Frequently Asked Questions

What are the regular maintenance tasks of the website?

Regular website maintenance is key to ensuring website security, stable operation, and user experience. Maintenance includes updating website content, checking and repairing website links, backing up data, conducting regular security checks, fixing vulnerabilities, optimizing performance, etc. These efforts help ensure that the website functions effectively over the long term and provides a good user experience.

How is UI and UX different in website design?

UI (User Interface) and UX (User Experience) are two important aspects of website design. UI focuses on the design, layout, and visual elements of a website, while UX focuses on the overall user experience and interaction experience on the website, including ease of use, navigation, interaction, etc. Good UI design often improves the user experience.

What are the types of website hosting services?

Website hosting services can be categorized into shared hosting, virtual private servers (VPS), dedicated servers, and cloud hosting. Shared hosting is when multiple websites share a server resource, VPS is a virtual private server, standalone server is a dedicated server, and cloud hosting provides hosting solutions based on cloud services, each type has different characteristics and applicable scenarios.

What does a website traffic statistics tool do?

Traffic statistics tools such as Google Analytics help analyze website visit data, including visitor sources, visits, and user behavior. By understanding this data, website owners can understand their audience, adjust website content and design, improve user experience, and increase conversion rates.

Request Quote

%{tishi_zhanwei}%